EL10N

Main characteristics
  • Electrolysis type: PEM (Proton exchange membrane, caustic free)
  • Number of cell stacks: 1
Hydrogen gas production
  • Max. nominal hydrogen flow: 10.05 Nm3/h (21.68 kg/day)
  • Hydrogen flow range: 10 -100%
  • Operating pressure: 15 – 40 barg (217-580 psig)
  • Hydrogen purity (before gas purification): > 99.9%; < 25 ppm O2; H2O saturated
  • Hydrogen purity (after gas purification): 99.999%; < 5 ppm O2; < 5 ppm H2O
Electrical requirements
  • Voltage: 3 x 400 VAC ± 10% (3Ph+N) / 3 x 480 VAC ± 10% (3Ph+N)
  • Frequency: 50 Hz ± 5% / 60 Hz ± 3%
  • Power (BoP + Stack):  53.2 kW
  • Stack consumption: 4.7 kWh/Nm3 H2
  • AC power consumption (BoP + stack): 5.3 kWh/Nm3 H2
Feed Water – Demi Water (optional Water Treatment Plant is not included)
  • Consumption: < 1 L/Nm3 H2
  • Conductivity: > 10 MΩcm (< 0.1 uS/cm); TOC < 30 ppb
  • Pressure: 2-3 barg (29-43 psig)
  • Temperature: +5 ºC to + 40 ºC (+41 ºF to +104 ºF)
Control system
  • PLC: Fully automated and unattended with 7″ color touch screen
  • Communication: Modbus TCP/IP or Profinet (RJ45 port)
Environmental conditions
  • Ambient temperature range: +5 ºC to + 45 ºC (+41 ºF to +113 ºF)
  • Humidity: 0 to +95% (non-condensing)
  • Air ventilation: Available from a non-hazardous area
  • Installation area: Indoor/Outdoor
Dimensions and weight
  • Dimensions (LxWxH): 10ft container (3.0m x 2.4m x 2.9) (9.8ft x 7.9ft x 9.5ft)
  • Approx. weight: 5,000 kg (11,023 lb)
Standards & regulations
  • Compliance: CE, ISO 22734-1 / NFPA 2-2016 & NFPA 70
Other characteristics
  • Duty cycle: 100% (24/7)
  • Start-up time (from stand-by): < 1 sec
  • Cold start time: < 5 min
  • Nitrogen Supply System: For each purge, consumption is <0.1 kg at 3 barg (to be supplied by the customer)
  • Instrumentation air System: Consumption 4 Nm3/h at 10 barg (to be supplied by the customer)

Always included

All our products do always incorporate:

N
Hydrogen cooling system
N
Emergency shutdown system
N
Overpressure relief system
N
Redundancy on critical safety parameters
N
Uninterruptible Power Supply (UPS)
N
Heat management (no cooling water is needed)
N
Virtual Private Network (VPN) connection

Additional Options

All our products can include:

L
Oxygen processing system
L
Hydrogen purification system (SAE J2719 September 2011)
L
Water treatment system
L
Extreme environmental conditions package (low and high temp)
L
Hydrogen Mass Flow Measure & Purity Measure (H2O & O2 Sensors)
L
Instrumentation air system
L
Nitrogen system

Products datasheet